GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC. General Electric P5-G5-S5-HI-AR-E. General Electric GE MULTILIN SR GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC, WITH CASE. General Electric P5-G5-S5-HI-AR-T-H. General Electric GE. Find great deals for GE Multilin Feeder Management Relay Sr Shop with confidence on eBay!.

Author: Ganos Sagar
Country: Thailand
Language: English (Spanish)
Genre: Science
Published (Last): 18 July 2006
Pages: 189
PDF File Size: 3.29 Mb
ePub File Size: 7.65 Mb
ISBN: 145-6-38611-664-6
Downloads: 95271
Price: Free* [*Free Regsitration Required]
Uploader: Kajigor

The baud rate of all the serial ports is variable from to 19, bps. The relay captures and stores the last events, recording the time, date, cause, and system parameters. The relay calculates the per-phase wear on the breaker contacts to establish a threshold.

When the measured quantity exceeds the pickup level, the relay can trigger an alarm or signal an output. A rear Ethernet port is also available as an optional feature. Event Recording The relay captures and stores the last events, recording the time, date, cause, and system parameters.

Fault Locator The relay uses captured data to calculate the type, distance to and the impedance of the fault. Events may be recorded selectively by category, so that only events of interest are recorded. Trace memory recording can be triggered by operation of selected features or logic inputs.

As an alternative, please refer to the relay. Two analog input level monitoring elements and two rate-of-change elements are available. When the breaker maintenance threshold is exceeded the relay can trigger an alarm.

VT Failure The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected.

General Electric GE MULTILIN SR CASE NEW

User Interface Various user interfaces facilitate operation of the The amount of pre-event data recorded is set by the user. This memory sr7500 be configured between the ranges of two to 16 blocks with 16 to power frequency cycles of data respectively. A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by te trip or alarm condition.

  ANGEL DE MEDIANOCHE LISA KLEYPAS PDF

Load shedding schemes based on voltage and frequency elements Back-up protection for transmission lines, feeders and transformers Distributed Generation DG interconnect protection. No need to disconnect any of the field wiring. The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected.

Oscillography A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays.

EnerVista 8 Series Setup Software provides automated setting file conversion.

Simply remove the terminal blocks and then remove the SR chassis from the panel. Once completed, a graphical report is sr7750 to verify and call out any specific settings that may need attention. The number of breaker trip operations is recorded, and can be displayed for statistical purposes useful for units gee operation counters. Breaker Conditions The relay calculates the per-phase wear on the breaker contacts to establish a threshold.

Any external quantity may be monitored via an auxiliary current input.

The can display 30 user-selected messages during keypad inactivity. Orders may be placed until 31st Decemberand will be fulfilled based upon availability.

Sr75 the new 8 Series Retrofit Kit users are able to install the Feeder Management System without modifying existing cutouts and wiring, and without any sr570 changes or re-engineering time. A failure to respond to an open or close signal in a programmed time can be used to generate be alarm.

  IPC 2221A FILETYPE PDF

Indicators Twenty LEDs indicate relay status, system status, and trip and alarm conditions. Insert the new 8 Series Retrofit chassis into the switchgear and simply plug-in the old terminal blocks – there is no need to make any cut-out modifications or push and pull cables.

Convenient COMTRADE and Sequence of Events viewers are an integral part of the Setup software included with every relay, to carry out postmortem event analysis to ensure proper protection system operation.

GE SR750 Multilin Power Management Reconditioned

This product is under last-time buy. About Grid Solutions GE’s Grid Solutions business serves customers globally with over 17, employees in approximately 80 countries. Analog Inputs Any external quantity may be monitored via an auxiliary current input. The relay uses captured data to calculate the type, distance to and the impedance of the fault. Grid Solutions helps enable utilities and industry to effectively manage electricity from the point of generation to the point of consumption, helping to maximize the reliability, efficiency and resiliency of the grid.

Records of the last 10 faults are stored. A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays.

An alarm is also generated if the relay detects sr7750 the supervisory trickle current is not present. The front panel port allows easy local computer access.